TM 9-2320-365-20-5 Change 2 20-197 (72) Apply sealing compound to threads of 90-degree return fitting (127), 90-degree fitting (121), plug (128), and four-way fitting (129). (73) Install 90-degree return fitting (127), 90-degree fitting (121), and plug (128) on four-way fitting (129). (74) Install four-way fitting (129) on fuel tank (122). (75) Connect fuel hose (120) to 90-degree return fitting (121). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. To prevent injury or death, keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. NOTE Install plastic cable ties as required.