TM 9-2320-365-20-5 Change 2 20-191 (37) Apply sealing compound to threads of fittings (72 and 73). (38) Install fitting (72) in inlet port (74) of fuel regulator (75). (39) Install fitting (73) in outlet port (76) of fuel regulator (75). (40) Install fuel tube (77) on fuel inlet port (63). (41) Route fuel tube (78) through hole (24) in pod panel (25). (42) Install fuel tubes (77 and 78) on fittings (72 and 73). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. To avoid injury or death keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel.