TM-9-2320-365-20-5 LMTV Unit Maintenance Manual M1078 Series - Volume 5 Download
Page 374 of 666
TM 9-2320-365-20-5 20-542 Change 2 20-90. DIGITIZATION KIT AFT STOWAGE BOX REPLACEMENT/REPAIR (CONT) (4) Apply sealant to threads of three snap screws (7). (5) Install three snap screws (7) on AFT Storage Box (2) with three lockwashers (8) and nuts (9). (6) Position bracket (10) on AFT Storage Box (2) with three washers (11) screws (12) and self-locking nuts (13). (7) Tighten three self-locking nuts (13) to 95-110 lb-in. (11-12 N•m). (8) Position side panel (14) on AFT Storage Box (2) with six washers (15), screws (16), and self-locking nuts (17). (9) Tighten six self-locking nuts (17) to 95-110 lb-in. (11- 12 N•m). WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel.