TM 9-2320-365-20-5 Change 2 20-537 (11) Apply sealant to threads of six screws (18) and eight screws (19). (12) Position top support (20) on rack assembly (2) with six washers (21) and screws (18). (13) Position eight washers (22) and screws (19) in top support (20). (14) Tighten two screws (12 and 13) to 70-85 lb-in. (8- 10 N•m). (15) Tighten three self-locking nuts (11) to 110-120 lb- in. (12-13 N•m). (16) Tighten six screws (18) to 70-85 lb-in. (8-10 N•m). (17) Tighten eight screws (19) to 110-120 lb-in. (12-13 N•m). e. Follow-on Maintenance (1) Install RH seat (Para 16-15) (2) Install digitization power cable (Para 20-81) (3) Install mounting base(s) and equipment. (4) Connect batteries (Para 7-57) End of Task WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel.