TM-9-2320-365-20-5 LMTV Unit Maintenance Manual M1078 Series - Volume 5 Download

Page 240 of 666

TM 9-2320-365-20-5 20-69. 200 AMP TERMINAL BLOCK REPLACEMENT (CONT) (13) Remove eight self-locking nuts (30), washers (31), screws (32), two terminal blocks (33), and identification plate (34) from bracket (28). Discard self-locking nuts. b. Installation. CAUTION Both terminal blocks must be positioned loosely to align correctly on mounting bracket before tightening hardware. Failure to comply may result in damage to equipment. (1) Position identification plate (1) and two terminal blocks (2) on bracket (3) with eight screws (4), washers (5), and self-locking nuts (6). (2) Tighten eight self-locking nuts (6) to 48 lb-in. (5 N·m). 20-410