TM-9-2320-365-20-5 LMTV Unit Maintenance Manual M1078 Series - Volume 5 Download
Page 232 of 666
TM 9-2320-365-20-5 20-68. 200 AMP TERMINAL BLOCK TO POWER DISTRIBUTION PANEL (PDP) 24 VDC CABLE REPLACEMENT (CONT) (6) Loosen clamp (9) on air compressor intake hose (10). (7) Remove air compressor intake hose (10) from intake air cleaner boot (11). (8) Loosen clamp (12) on intake air cleaner boot (11). (9) Remove intake air cleaner boot (11) from intake air cleaner housing (13). (10) Lift dust boot (14) on terminal lug TL44 (15). (11) Remove nut (16), lockwasher (17), washer (18), and terminal lug TL44 (15) from terminal block terminal (19). Discard lockwasher. NOTE Perform step (12) on M1079. (12) Remove terminal lug TL100 (20) from terminal block terminal (19). (13) Raise cab (TM 9-2320-365-10). (14) Remove spring pin (21) and suspension compression plate (22) from suspension compression plate stud (23). 20-402