TM-9-2320-365-20-5 LMTV Unit Maintenance Manual M1078 Series - Volume 5 Download

Page 228 of 666

TM 9-2320-365-20-5 20-67. 200 AMP TERMINAL BLOCK TO REVERSE POLARITY RELAY 24 VDC BATTERY CABLE REPLACEMENT (CONT) (6) Remove nut (10), lockwasher (11), washer (12), and terminal lugs TL1 (13) and TL166 (14) from terminal block terminal (15). Discard lockwasher. (7) Remove 200 amp terminal block to reverse polarity relay 24 vdc battery cable (9) from rear side of front lifting beam (16). (8) Remove convoluted tubing (17) from 200 amp terminal block to reverse polarity relay 24 vdc battery cable (9). b. Installation. NOTE Install plastic cable ties as required. (1) Install convoluted tubing (1) on 200 amp terminal block to reverse polarity relay 24 vdc battery cable (2). (2) Position 200 amp terminal block to reverse polarity relay 24 vdc battery cable (2) on rear side of front lifting beam (3). 20-398