TM 9-2320-365-20-5 20-66. 200 AMP TERMINAL BLOCK TO REVERSE POLARITY RELAY 12 VDC BATTERY CABLE REPLACEMENT (CONT) (3) Lift dust boot (4) on terminal lug TL173 (5). NOTE Remove plastic cable ties as required. (4) Remove nut (6), lockwasher (7), and terminal lug TL173 (5) from reverse polarity relay 12 VDC BAT terminal (8). Discard lockwasher. (5) Remove dust boot (4) from 200 amp terminal block to reverse polarity relay 12 vdc battery cable (9). (6) Remove convoluted tubing (10) from 200 amp terminal block to reverse polarity relay 12 vdc battery cable (9) and 200 amp terminal block to reverse polarity relay 12 vdc load cable (11). (7) Remove nut (12), lockwasher (13), washer (14), and terminal lug TL171 (15) from terminal block terminal (16). Discard lockwasher. (8) Remove 200 amp terminal block to reverse polarity relay 12 vdc battery cable (9) from rear side of front lifting beam (17). 20-394