TM-9-2320-365-20-5 LMTV Unit Maintenance Manual M1078 Series - Volume 5 Download

Page 208 of 666

TM 9-2320-365-20-5 20-62. 200 AMP TERMINAL BLOCK TO REVERSE POLARITY RELAY 24 VDC LOAD CABLE REPLACEMENT (CONT) (6) Remove nut (10), lockwasher (11), washer (12), and terminal lug TL167 (13) from terminal block terminal (14). Discard lockwasher. (7) Remove 200 amp terminal block to reverse polarity relay 24 vdc load cable (9) from rear side of front lifting beam (15). (8) Remove convoluted tubing (16) from 200 amp terminal block to reverse polarity relay 24 vdc load cable (9). b. Installation. NOTE Install plastic cable ties as required. (1) Install convoluted tubing (1) on 200 amp terminal block to reverse polarity relay 24 vdc load cable (2). (2) Route 200 amp terminal block to reverse polarity relay 24 vdc load cable (2) on rear side of front lifting beam (3). 20-378