TM-9-2320-365-20-5 LMTV Unit Maintenance Manual M1078 Series - Volume 5 Download
Page 201 of 666
TM 9-2320-365-20-5 b. Installation. (1) Position 200 amp terminal block to reverse polarity relay 12 vdc load cable (1) on rear side of front lifting beam (2). (2) Position terminal lug TL172 (3) on terminal block terminal (4) with washer (5), lockwasher (6), and nut (7). (3) Tighten nut (7) to 15-19 lb-ft (21-25 N·m). NOTE Install plastic cable ties as required. (4) Install convoluted tubing (8) on 200 amp terminal block to reverse polarity relay 12 vdc load cable (1) and 200 amp terminal block to reverse polarity relay 12 vdc battery cable (9). (5) Install dust boot (10) on 200 amp terminal block to reverse polarity relay 12 vdc load cable (1). (6) Position terminal lug TL174 (11) on reverse polarity relay (12) with lockwasher (13), and nut (14). (7) Tighten nut (14) to 108-132 lb-in. (12-15 N·m). (8) Position dust boot (10) on terminal lug TL174 (11). 20-371