TM-9-2320-365-20-5 LMTV Unit Maintenance Manual M1078 Series - Volume 5 Download

Page 200 of 666

TM 9-2320-365-20-5 20-60. 200 AMP TERMINAL BLOCK TO REVERSE POLARITY RELAY 12 VDC LOAD CABLE REPLACEMENT (CONT) NOTE Remove plastic cable ties as required. (3) Lift dust boot (4) on terminal lug TL174 (5). (4) Remove nut (6), lockwasher (7), and terminal lug TL174 (5) from reverse polarity relay (8). Discard lockwasher. (5) Remove dust boot (4) from 200 amp terminal block to reverse polarity relay 12 vdc load cable (9). (6) Remove convoluted tubing (10) from 200 amp terminal block to reverse polarity relay 12 vdc load cable (9) and 200 amp terminal block to reverse polarity relay 12 vdc battery cable (11). (7) Remove nut (12), lockwasher (13), washer (14), and terminal lug TL172 (15) from terminal block terminal (16). Discard lockwasher. (8) Remove 200 amp terminal block to reverse polarity relay 12 vdc load cable (9) from rear side of front lifting beam (17). 20-370