TM-9-2320-365-20-5 LMTV Unit Maintenance Manual M1078 Series - Volume 5 Download
Page 189 of 666
TM 9-2320-365-20-5 (5) Lift dust boot (11) on terminal lug TL169 (12). (6) Remove nut (13), lockwasher (14), and terminal lug TL169 (12) from reverse polarity relay 24V LOAD terminal (15). Discard lockwasher. (7) Lift dust boot (16) on terminal lug TL168 (17). (8) Remove nut (18), lockwasher (19), and terminal lug TL168 (17) from reverse polarity relay 24V BAT terminal (20). Discard lockwasher. NOTE Note orientation of reverse polarity relay prior to removal. (9) Remove two self-locking nuts (21), screws (22), and reverse polarity relay (23) from brackets (24 and 25). Discard self-locking nuts. b. Installation (All Models Except M1081). (1) Position reverse polarity relay (1) on brackets (2 and 3) with two screws (4) and self-locking nuts (5). (2) Tighten two self-locking nuts (5) to 22-27 lb-ft (31-37 N·m). 20-359