TM-9-2320-365-20-5 LMTV Unit Maintenance Manual M1078 Series - Volume 5 Download

Page 170 of 666

TM 9-2320-365-20-5 20-55. 200 AMP ALTERNATOR KIT REMOVAL (CONT) (49) Position intake air cleaner housing (5) on three mounting brackets (54) with three screws (53) and self-locking nuts (52). (50) Position washer (56) and screw (55) in resilient mount (57). (51) Tighten screw (55) to 26-31 lb-ft (35-42 N·m). (52) Tighten three self-locking nuts (52) to 35-51 lb-ft (47-69 N·m). (53) Install particle extraction hose (49) on adapter (50) with clamp (48). (54) Connect air filter restriction gauge hose (46) to air flow sensor (47). (55) Install connector J106 (42) and dust cap lanyard (44) on chemical detection unit mounting bracket (45) with nut (43). (56) Install dust cap (41) on connector J106 (42). 20-340