TM 9-2320-365-20-5 (119) Remove two nuts (124) and lockwashers (125) from reverse polarity relay 24V LOAD terminal (126) and 24V BAT terminal (127). (120) Install dust boot (128) on 12vdc load cable (84). (121) Install dust boot (129) on 12vdc battery cable (85). (122) Install dust boot (130) on 24vdc load cable (81). (123) Install dust boot (131) on 24vdc battery cable (82). (124) Position terminal lug TL169 (134) on reverse polarity relay 24V LOAD terminal (126) with lockwasher (125) and nut (124). (125) Position terminal lug TL168 (135) on reverse polarity relay 24V BAT terminal (127) with lockwasher (125) and nut (124). (126) Tighten two nuts (124) to 30 lb-ft (41 N·m). (127) Position dust boots (130 and 131) on terminal lugs TL169 (134) and TL168 (135). 20-331