TM-9-2320-365-20-5 LMTV Unit Maintenance Manual M1078 Series - Volume 5 Download

Page 159 of 666

TM 9-2320-365-20-5 (100) Position terminal lug TL169 (134) on reverse polarity relay 24V LOAD terminal (126) with lockwasher (125) and nut (124). (101) Position terminal lug TL168 (135) on reverse polarity relay 24V BAT terminal (127) with lockwasher (125) and nut (124). (102) Tighten two nuts (124) to 27-33 lb-ft (37-47 N·m). (103) Install dust boots (130 and 131) on terminal lugs TL169 (134) and TL168 (135). NOTE Perform steps (104) through (131) on M1081 only. (104) Remove self-locking nut (136) and screw (137) from spare tire retainer (138). Discard self-locking nut. (105) Remove screw (139) and spring washer (140) from front lifting beam (86). Discard spring washer. (106) Position bracket (141) on spare tire retainer (138) with screw (137) and self-locking nut (136). (107) Position bracket (141) on front lifting beam (86) with spring washer (140) and screw (139). (108) Tighten self-locking nut (136) to 43-51 lb-ft (58-69 N·m). (109) Tighten screw (139) to 43-51 lb-ft (58-69 N·m). Change 1 20-329