TM-9-2320-365-20-5 LMTV Unit Maintenance Manual M1078 Series - Volume 5 Download
Page 159 of 666
TM 9-2320-365-20-5  (100) Position terminal lug TL169 (134) on reverse polarity  relay 24V LOAD terminal (126) with lockwasher (125)  and nut (124).  (101) Position terminal lug TL168 (135) on reverse polarity  relay 24V BAT terminal (127) with lockwasher (125) and  nut (124).  (102) Tighten two nuts (124) to 27-33 lb-ft (37-47 N·m).  (103) Install dust boots (130 and 131) on terminal lugs TL169  (134) and TL168 (135).  NOTE  Perform steps (104) through (131) on M1081  only.  (104) Remove self-locking nut (136) and screw (137) from  spare tire retainer (138). Discard self-locking nut.  (105) Remove screw (139) and spring washer (140) from front  lifting beam (86). Discard spring washer.  (106) Position bracket (141) on spare tire retainer (138) with  screw (137) and self-locking nut (136).  (107) Position bracket (141) on front lifting beam (86) with  spring washer (140) and screw (139).  (108) Tighten self-locking nut (136) to 43-51 lb-ft (58-69 N·m).  (109) Tighten screw (139) to 43-51 lb-ft (58-69 N·m).  Change 1 20-329