TM-9-2320-365-20-5 LMTV Unit Maintenance Manual M1078 Series - Volume 5 Download

Page 145 of 666

TM 9-2320-365-20-5 (4) Remove terminal lug TL6 (6) from dust boot (7). NOTE Retain 24vdc and 12vdc cable assemblies for future installation. (5) Remove three screws (8), washers (9), clamps (10), 24vdc cable (11), and 12vdc cable (12) from air inlet manifold (13). (6) Remove three clamps (10) from 24 vdc cable (11) and 12 vdc cable (12). (7) Remove self-locking nut (14) and washer (15) from alternator (16). CAUTION Ensure pulley does not contact wires, terminal lugs, or terminal screws on front of alternator. Failure to comply may result in damage to equipment. (8) Position pulley (17) on alternator (16) with washer (15) and self-locking nut (14). (9) Position pulley (17) in vise. (10) Tighten self-locking nut (14) to 106-130 lb-ft (144-176 N·m). (11) Remove pulley (17) from vise. Change 1 20-315