TM 9-2320-365-20-5  Change 2 20-256.7  (8) Apply sealing compound to threads of two fittings  (14).  (9) Install two fittings (14) in couplings (19).  (10) Install capacitor (24) on pump box (5) with terminal  lug TL526 (25), washer (26), and screw (27).  (11) Connect fuel pump connector (28) to connector P46  (29).  WARNING  Adhesives, solvents, and sealing  compounds can burn easily, can give  off harmful vapors, and are harmful to  skin and clothing. To avoid injury or  death, keep away from open fire and  use in a well-ventilated area. If  adhesive, solvent, or sealing  compound gets on skin or clothing,  wash immediately with soap and  water. Failure to comply may result in  injury to personnel.