TM-9-2320-365-20-5 LMTV Unit Maintenance Manual M1078 Series - Volume 5 Download

Page 106 of 666

TM 9-2320-365-20-5 20-47. M1079 HEATER FUEL REGULATOR REPLACEMENT (CONT) (4) Disconnect connector P4A (11) from connector J4 (12). (5) Remove heater power cable (13) from heater cover (9). WARNING Diesel fuel is flammable. If fuel is spilled, clean it up immediately. Failure to comply may result in serious injury or death to personnel. NOTE • Tag tubes and connection points prior to disconnecting. • Note position of fittings and fuel regulator prior to removal. (6) Disconnect fuel tubes (14 and 15) from fittings (16 and 17). 20-252