TM 9-2320-365-20-5  Change 2 20-247  (20) Apply sealing compound to threads of fittings (27  and 28).  (21) Install fittings (27 and 28) on two bushings (19).  (22) Position two clamps (29) on hoses (30 and 31).  (23) Install hoses (30 and 31) on fittings (27 and 28) with  two clamps (29).  (24) Install two fittings (32) on pod frame (33) with two nuts  (34).  (25) Apply sealing compounds to threads of fittings (35 and  36).  (26) Install fittings (35 and 36) on two fittings (32).  (27) Position two clamps (37) on hoses (30 and 31).  (28) Install hoses (30 and 31) on fittings (35 and 36) with  two clamps (37).  (29) Install adapters (38 and 39) on two fittings (32).  WARNING  Adhesives, solvents, and sealing com-  pounds can burn easily, can give off  harmful vapors, and are harmful to skin  and clothing. To avoid injury or death,  keep away from open fire and use in a  well-ventilated area. If adhesive, solvent,  or sealing compound gets on skin or  clothing, wash immediately with soap  and water. Failure to comply may result  in injury to personnel.