TM-9-2320-365-20-4 LMTV Unit Maintenance Manual M1078 Series - Volume 4 Download

Page 748 of 968

TM 9-2320-365-20-4 19-13. HYDRAULIC RESERVOIR AND BRACKET REPLACEMENT (CONT) NOTE Apply lubricating oil to preformed packings during installation. (9) Install preformed packing (15) on 90-degree fitting (16). (10) Install 90-degree fitting (16) in hydraulic reservoir (17). (11) Install preformed packing (18) on fitting (19). (12) Install fitting (19) in hydraulic reservoir (17). (13) Position hydraulic reservoir (17) in bracket (1) with strap (12) positioned around hydraulic reservoir (17). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well- ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, washer immediately with soap and water. Failure to comply may result in injury to personnel. (14) Apply sealing compound to threads of nut (20). (15) Position nut (20) on strap (12). (16) Tighten nut (20) to 42-52 ft-lb (57-71 N m). (17) Connect hose (21) to fitting (19). (18) Connect hose (22) to 90-degree fitting (16). c. Follow-On Maintenance. (1) Install hydraulic oil filter assembly (para 19-12). (2) Fill hydraulic reservoir (TM 9-2320-365-10). End of Task. 19-64