TM-9-2320-365-20-4 LMTV Unit Maintenance Manual M1078 Series - Volume 4 Download
Page 703 of 968
TM 9-2320-365-20-4  (24) Install preformed packing (49) on plug (50).  (25) Position plug (50) in hydraulic manifold (2).  (26) Tighten plug (50) to 13 lb-ft (18 N·m).  WARNING  Adhesives, solvents, and sealing com-  pounds can burn easily, can give off  harmful vapors, and are harmful to skin  and clothing. Keep away from open fire  and use in a well-ventilated area. If  adhesive, solvent, or sealing compound  gets on skin or clothing, wash  immediately with soap and water. Failure  to comply may result in injury to  personnel.  (27) Apply sealing compound to threads of plug (51).  (28) Position preformed packing (52), check valve (53),  setscrew (54), and plug (51) in hydraulic manifold (2).  (29) Tighten plug (51) to 21 lb-ft (28 N·m).  (30) Install breather cap (55) in hydraulic manifold (2).  (31) Apply antiseize compound to four air fittings (56).  (32) Install four air fittings (56) in hydraulic manifold (2).  (33) Install eight preformed packings (57) on fittings (58).  (34) Install eight fittings (58) in hydraulic manifold (2).  (35) Install two preformed packings (59) on 45-degree fittings  (60).  (36) Install two 45-degree fittings (60) in hydraulic manifold  (2).  Change 1 19-20.13