TM 9-2320-365-20-4 19-4. HYDRAULIC MANIFOLD REPLACEMENT/REPAIR (CONT) (16) Install preformed packings (34, 35, and 36) and back-up rings (37 and 38) on cartridge valve (39). (17) Position cartridge valve (39) in hydraulic manifold (2). (18) Tighten cartridge valve (39) to 40 lb-ft (54 N·m). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (19) Apply sealing compound to threads of plug (40). (20) Position check valve (41), preformed packing (42), spacer (43), setscrew (44), and plug (40) in CV1 orifice (45). (21) Tighten plug (40) to 21 lb-ft (28 N·m). (22) Install two preformed packings (46) on plugs (47). (23) Install two filters (48) and plugs (47) in hydraulic manifold (2). 19-20.12 Change 1