TM-9-2320-365-20-4 LMTV Unit Maintenance Manual M1078 Series - Volume 4 Download
Page 625 of 968
TM 9-2320-365-20-4 CAUTION Cap or plug hoses and personnel heater coil to prevent contamination of cooling system. Failure to comply may result in damage to equipment. NOTE • Tag hoses prior to disconnecting. • Remove plastic cable ties as required. (11) Loosen clamps (21 and 22) on hoses (23 and 24). (12) Disconnect hoses (23 and 24) from personnel heater coil (25). (13) Remove clamps (21 and 22) from hoses (23 and 24). (14) Remove personnel heater coil (25) from personnel heater (17). (15) Remove seal (26) from personnel heater coil (25). (16) Remove hose (24) from personnel heater (17). (17) Loosen clamp (27) on hose (23). (18) Disconnect hose (23) from valve (28). (19) Remove clamp (27) from hose (23). 18-37