TM 9-2320-365-20-4 16-72. M1079 12/24 VDC POWER ENTRY PANEL AND CONDUIT REPLACEMENT (CONT) WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. CAUTION Coat all rivets with sealing compound prior to installation. Failure to comply may result in damage to equipment. (7) Apply sealing compound on van body wall (15) and rivets (16). NOTE Perform step (8) on van bodies serial number 191 and higher. (8) Install 12/24 vdc power entry panel (17) on van body wall (15) with 14 rivets (16). NOTE Perform step (9) on van body serial numbers 001 through 190. (9) Install 12/24 vdc power entry panel (17) on van body wall (15) with 22 rivets (16). (10) Apply sealing compound on edges of 12/24 vdc power entry panel (17). 16-482