TM 9-2320-365-20-4 (6) Perform steps (2) through (5) on remaining wires. NOTE Steps (7) and (8) require the aid of an assistant. (7) Install gasket (1) and 12/24 vdc power entry connector J173 (2) in 12/24 vdc power entry panel (6) with three screws (7), lockwashers (8), and nuts (9). (8) Install dust cap (10) on 12/24 vdc power entry connector J173 (2) with screw (11), lockwasher (12), and nut (13). WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (9) Apply sealing compound on edges of 12/24 vdc power entry connector J173 (2). (10) Install dust cap (10) on 12/24 vdc power entry connector J173 (2). NOTE Perform step (11) on van bodies serial number 191 and higher. (11) Install cover (14) on 12/24 vdc power entry panel (6) with four washers (15), lockwashers (16), and screws (17). 16-477