TM-9-2320-365-20-4 LMTV Unit Maintenance Manual M1078 Series - Volume 4 Download
Page 524 of 968
TM 9-2320-365-20-4  16-71. M1079 12/24 VDC POWER ENTRY CONNECTOR REPLACEMENT (CONT)  NOTE  • All wires on 12/24 vdc power entry connector  are removed the same way. One wire shown.  • Tag wires and connection points prior to  disconnecting.  • Refer to Table 16-9. M1079 Connector J173  Pin Letters and Wire Numbers for details.  (7) Remove wire (15) from 12/24 vdc power entry connector  J173 pin (16).  (8) Remove insulation sleeving (17) from wire (15).  (9) Perform steps (7) and (8) on remaining wires.  (10) Remove gasket (14) from 12/24 vdc power entry  connector J173 (7). Discard gasket.  Table 16-9. M1079 Connector J173 Pin Letters and Wire Numbers  PIN LETTER A B C D E F G H  WIRE NUMBER 2010 3086 2040 3086 UNUSED 2006 1507 1507  b. Installation.  NOTE  • All wires on 12/24 vdc power entry connector  are installed the same way. One wire shown.  • Refer to Table 16-9. M1079 Connector J173  Pin Letters and Wire Numbers for details.  (1) Position gasket (1) on 12/24 vdc power entry connector  J173 (2).  (2) Position insulation sleeving (3) on wire (4).  (3) Remove approximately 1/4 in. (0.6 cm) of insulation from  wire (4).  (4) Solder wire (4) to 12/24 vdc power entry connector J173  pin (5).  (5) Shrink insulation sleeving (3) on wire (4) and 12/24 vdc  power entry connector J173 pin (5).  16-476