TM 9-2320-365-20-4 16-68. M1079 110/208 VAC POWER IN/OUT CABLE REPLACEMENT (CONT) (3) Install four washers (7), lockwashers (8), and nuts (9) on screw (5) and three screws (6). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (4) Apply sealing compound on heads of screws (5 and 6) and edges of 110/208 vac POWER OUT connector (2). (5) Install dust cap (4) on 110/208 vac POWER OUT connector (2). 16-460