TM-9-2320-365-20-4 LMTV Unit Maintenance Manual M1078 Series - Volume 4 Download
Page 486 of 968
TM 9-2320-365-20-4 16-66. M1079 110/208 VAC POWER DISTRIBUTION PANEL REPLACEMENT (CONT) (30) Install wires 502 (56), 501 (57), and 500 (58) on 200 amp AC circuit breaker (59). (31) Tighten three screws (60) in 200 amp AC circuit breaker (59). c. Follow-On Maintenance. (1) Install 15/20/30 and 50 amp AC circuit breakers (para 16-64). (2) Check for proper operation of AC electrical system (TM 9-2320-365-10). End of Task. 16-438