TM 9-2320-365-20-4 16-64. M1079 15/20/30 AND 50 AMP AC CIRCUIT BREAKER REPLACEMENT This task covers: a. Removal b. Installation c. Follow-On Maintenance INITIAL SETUP Equipment Conditions AC power disconnected (TM 9-2320-365-10). Batteries disconnected (para 7-48). LH and RH doors opened (115 degrees) (TM 9-2320- 365-10). Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) Materials/Parts Dispenser, Pressure Sensitive Adhesive Tape (Item 21, Appendix D) a. Removal. (1) Remove six screws (1) and 110/208 VAC POWER DISTRIBUTION PANEL cover (2) from 110/208 vac power distribution box (3). 16-419