TM-9-2320-365-20-4 LMTV Unit Maintenance Manual M1078 Series - Volume 4 Download

Page 445 of 968

TM 9-2320-365-20-4 16-62. M1079 110 VAC AND 24 VDC RELAY REPLACEMENT This task covers: a. Removal b. Installation c. Follow-On Maintenance INITIAL SETUP Equipment Conditions AC power disconnected (TM 9-2320-365-10). Batteries disconnected (para 7-48). LH and RH doors opened (115 degrees) (TM 9-2320- 365-10). Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) a. Removal. (1) Loosen screw (1) on cover (2). (2) Open cover (2) on relay box (3). NOTE All relays are replaced the same way. Relay K35 shown. (3) Remove relay K35 (4) from relay socket (5). 16-397