TM 9-2320-365-20-4 (6) Install flexible conduit (3) on LH door (17) with two clamps (18) and screws (19). (7) Install switch S17 (20) on conduit connector (2). (8) Install switch S17 (20) on plate (21) with four lockwashers (22) and screws (23). (9) Position wire 1506 (6) on switch S17 (20). (10) Tighten screw 1 (24) in switch S17 (20). (11) Position wire 2006 (7) on switch S17 (20). (12) Tighten screw 2 (25) in switch S17 (20). 16-361