TM 9-2320-365-20-4 (13) Install conduit connector (26) in 110 vac outlet box (27). (14) Route supply wire(s) (5), neutral wire (6), ground wire (7) through conduit connector (26). (15) Install conduit nut (18) on conduit connector (26). (16) Install two screws (28) in outlet box (27). (17) Install ground jumper wire terminal lug (29) on outlet box (27). (18) Tighten screw (30) in outlet box (27). NOTE Perform step (19) and (20) on right side 110 vac outlets J232, J231, and J230. (19) Install supply wire terminal lugs (10 and 11) on receptacle (31). (20) Tighten two screws (32) in receptacle (31). NOTE Perform step (21) and (22) on left side 110 vac outlets J233, J234, and J235. (21) Install supply wire terminal lug (10) on receptacle (31). (22) Tighten screw (32) in receptacle (31). 16-347