TM 9-2320-365-20-4 NOTE • Perform steps (3) through (6) on all 110 vac outlets. • Tag wires and connection points prior to disconnecting. • Refer to Table 16-4. M1079 110 VAC Outlet Box Location and Wire Numbers for details. (3) Loosen screw (6) in receptacle (5). (4) Remove neutral wire terminal lug (7) from receptacle (5). (5) Loosen green screw (8) in receptacle (5). (6) Remove ground wire and jumper wire terminal lugs (9 and 10) from receptacle (5). Table 16-4. M1079 110 VAC Outlet Box Location and Wire Numbers Location Outlet Number Outlet Wiring Supply Neutral Ground Left Front J233 702D (Bottom) 1499G (Top) 3085W 3085AF (Jumper) Left Middle J234 702E (Bottom) 1499E (Top) 3085H 3085AE (Jumper) Left Rear J235 702F (Bottom 1499F (Top) 3085G 3085AG (Jumper) Right Front J232 702D (Top) 702A (Bottom) 1499B (Top) 3085K 3085AA (Jumper) Right Middle J231 702E (Top) 702B (Bottom) 1499C (Top) 3085M 3085AB (Jumper) Right Rear J230 702F (Top) 702C (Bottom) 1499D (Top) 3085J 3085AC (Jumper) 16-341