TM-9-2320-365-20-4 LMTV Unit Maintenance Manual M1078 Series - Volume 4 Download

Page 375 of 968

TM 9-2320-365-20-4 16-52. M1079 24 VDC BINDING POST/BOX AND CONDUIT REPLACEMENT This task covers: a. Removal b. Installation c. Follow-On Maintenance INITIAL SETUP Equipment Conditions AC power disconnected (TM 9-2320-365-10). Batteries disconnected (para 7-48). 110 vac outlet/box and conduit removed (for removal of 24 vdc box or conduit) (para 16-53). Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) Tool Kit, Auto Fuel and Electrical Systems Repair (Item 42, Appendix C) Materials/Parts Dispenser, Pressure Sensitive Adhesive Tape (Item 21, Appendix D) Lockwasher (12) (Item 76, Appendix G) Terminal, Lug (5) (Item 266, Appendix G) a. Removal. NOTE Left side and right side 24 vdc POS, NEG, and GND binding posts are removed the same way. Right side (J237) 24 vdc POS binding post shown. (1) Remove two screws (1) and cover (2) from outlet box (3). 16-327