TM 9-2320-365-20-4 (5) Remove binding post (8), preformed packing (13), nylon washer (14), and preformed packing (15) from 110/208 vac power entry panel (5). b. Exterior Field Telephone Binding Post Installation. NOTE • Both exterior field telephone binding posts are installed the same way. Negative exterior field telephone binding post shown. • Steps (1) through (3) require the aid of an assistant. (1) Install preformed packing (1), nylon washer (2), preformed packing (3), and binding post (4) in 110/208 vac power entry panel (5). (2) Install nylon washer (6), washer (7), lockwasher (8), and nut (9) on binding post (4). NOTE Positive field telephone binding post wire number is 424. (3) Install wire 425 terminal lug (10) on binding post (4) with nut (11). 16-315