TM-9-2320-365-20-4 LMTV Unit Maintenance Manual M1078 Series - Volume 4 Download

Page 258 of 968

TM 9-2320-365-20-4 16-35. M1079 RH DOOR ASSEMBLY REPLACEMENT/REPAIR (CONT) WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (12) Apply sealing compound around heads of six screws (5 and 9) and completely around edges of three hinges (8). (13) Install conduit (10) on RH door (3) with two clamps (11) and screws (12). (14) Position bracket (13) on RH door (3) with two washers (14), lockwashers (15), and screws (16). (15) Apply sealing compound to two rivets (17) and rivet nut (18). (16) Install rivet nut (18) in plate (19). (17) Apply sealing compound to back of plate (19). (18) Install plate (19) on RH door (3) with two rivets (17). 16-210