TM-9-2320-365-20-4 LMTV Unit Maintenance Manual M1078 Series - Volume 4 Download

Page 251 of 968

TM 9-2320-365-20-4 (21) Open vent cover (13) on RH door (5). (22) Install air filter (20) in filter frame (11). (23) Close vent cover (13) on RH door (5). (24) Latch stud base fastener (17) on vent cover (13). (25) Install latch (21) on RH door (5) with four washers (22), lockwashers (23), and screws (24). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (26) Apply sealing compound around edge of latch (21) and screws (24). 16-203