TM 9-2320-365-20-4 16-16. TOOL BOX REPLACEMENT/REPAIR (CONT) (10) Adjust position of latch pawl (11) on shaft (6) so that tool box door (3) is flush against tool box (13) when bail (4) is turned to locked position. (11) Tighten setscrew (16) in latch pawl (11). b. Installation. (1) Position tool box (1) on backup hydraulic pump (2) with two washers (3) and screws (4). (2) Tighten two screws (4) to 28-34 lb-ft (38-46 N·m). NOTE Step (3) requires the aid of an assistant. (3) Position tool box (1) on front lifting beam (5) with two washers (6), screws (7), and self-locking nuts (8). (4) Tighten two self-locking nuts (8) to 43-52 lb-ft (58-71 N·m). 16-120