TM 9-2320-365-20-3 WARNING WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvents, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (10) Apply sealing compound to threads of two screws (11). (11) Position CTIS manifold valve (12) on mounting bracket (1) with two screws (11). (12) Tighten two screws (11) to 15-17 lb-ft (20-23 N·m). (13) Install filter (13) in CTIS manifold valve (12). (14) Install preformed packing (14) on CTIS hose (15). (15) Install CTIS hose assembly (15) on CTIS manifold valve (12). (16) Install CTIS hose (15) on adapter (8). (17) Install preformed packing (16) on CTIS hose (17). (18) Install CTIS hose (17) on CTIS manifold valve (12). 12-13