TM 9-2320-365-20-3 b. Installation WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply antiseize compound to threads of fitting (1), run tee fitting (2), branch tee fitting (3), 90-degree fitting (4), reducer bushing (5), and air pressure transmitter (6). (2) Install fitting (1) in two-way check valve (7). (3) Install run tee fitting (2) in two-way check valve (7). (4) Install branch tee fitting (3) in two-way check valve (7). (5) Install 90-degree fitting (4) in branch tee fitting (3). (6) Install reducer bushing (5) in tee fitting (3). (7) Install low pressure transmitter (6) in reducer bushing (5). (8) Install two-way check valve (7) on cab (8) with washer (9) and screw (10). Change 1 11-141