TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download
Page 879 of 1268
TM 9-2320-365-20-3  (5) Disconnect air hose (9) from 90-degree fitting (10).  (6) Remove 90-degree fitting (10) from adapter (6).  (7) Remove nut (11), lockwasher (12), adapter (6),  identification plate (13), and plate (14) from mounting  bracket (4). Discard lockwasher.  b. Installation.  NOTE  • Both front gladhands are installed the same  way. Service gladhand shown.  • Install plastic cable ties as required.  (1) Install plate (1), identification plate (2), and adapter (3)  on mounting bracket (4) with lockwasher (5) and nut (6).  WARNING  Adhesives, solvents, and sealing com-  pounds can burn easily, can give off  harmful vapors, and are harmful to  skin and clothing. Keep away from  open fire and use in a well-ventilated  area. If adhesive, solvent, or sealing  compound gets on skin or clothing,  wash immediately with soap and water.  Failure to comply may result in injury  to personnel.  (2) Apply antiseize compound to threads of 90-degree  fitting (7).  (3) Install 90-degree fitting (7) in adapter (3).  (4) Connect air hose (8) to 90-degree fitting (7).  11-117