TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download

Page 875 of 1268

TM 9-2320-365-20-3 (10) Remove drain valve (13) from primary air tank (11). d. Primary Air Tank Installation. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply antiseize compound to threads of drain valve (1). (2) Install drain valve (1) in primary air tank (2). 11-113