TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download
Page 851 of 1268
TM 9-2320-365-20-3 (10) Disconnect four air hoses (14) from 90-degree fittings (15). (11) Remove TRAILER AIR SUPPLY valve (3) from personnel heater assembly (8). NOTE Note orientation of fittings prior to removal. (12) Remove four 90-degree fittings (15) from TRAILER AIR SUPPLY valve (3). b. Installation. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply antiseize compound to threads of four 90-degree fittings (1). (2) Install four 90-degree fittings (1) in TRAILER AIR SUPPLY valve (2). Change 1 11-93