TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download
Page 839 of 1268
TM 9-2320-365-20-3 b. Air Brake Protecting Valve Installation. WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply antiseize compound to threads of plug (1), bushing (1.1), relief valve (2), run tee fitting (3), two 45- degree fittings (4), 90-degree fitting (5) and fitting (6). (2) Install plug (1) in air brake protecting valve (7). (2.1) Install bushing (1.1) in air brake protecting valve (7). (3) Install relief valve (2) in air brake protecting valve (7). (4) Install run tee fitting (3) in air brake protecting valve (7). (5) Install two 45-degree fittings (4) in air brake protect-ing valve (7). (6) Install 90-degree fitting (5) in air brake protecting valve (7). (7) Install fitting (6) in air brake protecting valve (7). (8) Position air brake protecting valve (7) on panel (8) with two washers (9), screws (10) and self-locking nuts (11). (9) Tighten two self-locking nuts (11) to 14-18 lb-ft (20-24 N·m). Change 1 11-83