TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download
Page 824 of 1268
TM 9-2320-365-20-3 11-12. INVERSION VALVE REPLACEMENT (CONT) b. Installation. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (1) Apply antiseize compound to threads of branch tee fitting (1), two 90-degree fittings (2), and run tee fitting (3). (2) Install branch tee fitting (1) in inversion valve (4). (3) Install two 90-degree fittings (2) in inversion valve (4). (4) Install run tee fitting (3) in inversion valve (4). (5) Position inversion valve (4) on panel (5) with two washers (6), screws (7) and self-locking nuts (9). (6) Tighten two self-locking nuts (9) to 14-18 lb-ft (20-24 N·m). 11-68 Change 1