TM 9-2320-365-20-3 11-10. LOAD SENSING VALVE AND CONTROL CABLE REPLACEMENT/ADJUSTMENT (CONT) CAUTION Load sensing valve control cable must be installed in cable clamp on back side of control lever, opposite cable clamp screw. Failure to comply may result in damage to load sensing valve control cable. (11) Install load sensing valve control cable (16) in cable clamp (17). (12) Perform load sensing valve adjustment. e. Load Sensing Valve Adjustment. WARNING Proper adjustment may only be accomplished with vehicle unloaded. Failure to comply may result in injury to personnel or damage to equipment. (1) Position cable clamp (1) on control lever (2) so that center of cable clamp measures 5 3/8 - 5 5/8 in. (13.65- 14.29 cm) from center of pivot shaft (3). (2) Position control lever (2) so that it is level. (3) Tighten screw (4) in cable clamp (1). 11-58