TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download
Page 805 of 1268
TM 9-2320-365-20-3 (6) Connect connector PX17 (9) to master power switch (10). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (7) Apply antiseize compound to threads of stoplight switches (11 and 12). (8) Install stoplight switches (11 and 12) in foot control valve (1). (9) Install terminal lugs TL155 (13) and TL154 (14) on front stoplight switch (11) with two lockwashers (15) and nuts (16). (10) Install terminal lugs TL153 (17) and TL152 (18) on rear stoplight switch (12) with two lockwashers (19) and nuts (20). Change 1 11-51