TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download
Page 79 of 1268
TM 9-2320-365-20-3 (13) Deleted. (14) Deleted. (15) Deleted. (16) Deleted. (17) Position preformed packing (25) and fuel level sending unit (26) in fuel tank (23) with five screws (27). (17.1) Tighten five screws (27) to 20-24 lb-in. (2-3 N·m). WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (18) Apply sealing compound primer to threads of 90-degree return fitting (28), 90-degree pickup tube fitting (29), and relief valve (30). (19) Apply sealing compound to threads of 90-degree return fitting (28), 90-degree pickup tube fitting (29), and relief valve (30). (20) Install 90-degree return fitting (28) in fuel tank (23). (21) Install 90-degree pickup tube fitting (29) in fuel tank (23). (22) Install relief valve (30) in fuel tank (23). Change 1 4-47