TM-9-2320-365-20-3 LMTV Unit Maintenance Manual M1078 Series - Volume 3 Download

Page 789 of 1268

TM 9-2320-365-20-3 b. Installation. WARNING Adhesives, solvents, and sealing com- pounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. NOTE Left and right front brake air chambers are installed the same way. Left side shown. (1) Apply antiseize compound to threads of two fittings (1). (2) Install two fittings (1) in air chamber (2). (3) Position collet nut (3) on air chamber (2). (4) Apply antiseize compound to threads of air chamber (2). CAUTION Ensure air chamber is installed with fittings positioned up. Failure to comply may result in damage to equipment. (5) Install air chamber (2) in plunger housing (4) until it bottoms. CAUTION Air chamber must not be loosened no more than one full turn. Failure to comply may result in damage to equipment. (6) Loosen air chamber (2) until fittings (1) are up. Change 1 11-35