TM 9-2320-365-20-3 11-5. REAR BRAKE PLUNGER ASSEMBLY REPLACEMENT/REPAIR (CONT) c. Cleaning/Inspection. WARNING Dry Cleaning Solvent is toxic and flammable. Wear protective goggles, face shield, and gloves; use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when using solvent. The flashpoint for Type I Dry Cleaning Solvent is 100°F (38°C) and for Type II Dry Cleaning Solvent is 140°F (60°C). Failure to comply may result in serious injury or death to personnel. (1) Clean all metal parts thoroughly with dry cleaning solvent. NOTE Replace plungers, sleeves, screws, springs, and pawls as a unit. (2) Inspect adjusting plunger (1), adjusting sleeve (2), and adjusting screw (3) for damage. (3) Inspect screw (4), spring (5), and adjusting pawl (6) for damage. (4) Inspect anchor plunger (7) and guide screw (8) for damage. (5) Inspect rollers (9) for freedom of movement, and pitting or cracks. (6) Inspect spring (10) for cracks, distortion, or corrosion. (7) Inspect rubber (11) for deterioration or damage. 11-26